How to Control Junctions in Sessions
From TrainzOnline
(Difference between revisions)
m (→Application 2: Asking the User to Set Junctions) |
m (→Related Trainz Wiki Links:) |
||
Line 70: | Line 70: | ||
*'''[[Navigation Point Applications|Navigation Point Applications]]''' | *'''[[Navigation Point Applications|Navigation Point Applications]]''' | ||
*'''[[Navigation Point Rules Examples|Navigation Point Rules Examples]]''' | *'''[[Navigation Point Rules Examples|Navigation Point Rules Examples]]''' | ||
+ | *'''[[Parent and Child Rules]]''' | ||
*'''[[Using Variables in Sessions - Examples|Using Variables in Sessions - Examples]] | *'''[[Using Variables in Sessions - Examples|Using Variables in Sessions - Examples]] |
Revision as of 21:55, 17 May 2018
The screenshots shown below give examples of how junction settings can be used to control the operation of a session.
Application 1: Presetting Junctions
1. The Scenario:
When a consist reaches a trigger, the junctions ahead are set and locked into position.
2. Rules Used:
- Trigger Check Rule to trigger the event.
- Set Junctions Rule to set junctions.
3. Session Rules Screenshot:
4. Example Explanation:
- Line 1: Trigger Check The event is triggered when the consist reaches a trigger. This executes the following rule.
- Line 2: Set Junctions Sets selected junctions to set directions and specifies the level of control by the users and AI.
Application 2: Asking the User to Set Junctions
1. The Scenario:
A consist has been halted at a trigger placed in front of a junction. The user will be asked to set that junction and the following junction before the consist can proceed.
2. Rules Used:
- Wait on Navigation Point Rule to trigger the event.
- Message Popup Rule to open a message window on the screen.
- Multiple Junction Alignment Check Rule to test if specified junctions are set correctly.
3. Session Rules Screenshot:
4. Example Explanation:
- Line 1: Wait on Navigation Point The event is triggered when the consist halts at the navigation point assigned to the trigger. This executes the following rules simultaneously
- Line 2: Message Popup Displays a message window asking that the next two junctions be manually set.
- Line 3: Multiple Junction Alignment Check tests the switch directions of the next two junctions and waits until they are aligned as specified.
Checking junction switch settings |
The following line is executed only if the junctions are set correctly
- Line 4: Message Popup Displays a message window stating that the junctions are now correctly set.